Dear RTCU User,
This RTCU Newsletter is sent out to inform you about the latest
firmware release now available.
Upgrading to this firmware release is only recommended for applications that is
experiencing the issues specifically solved and/or in the case where the
enhancements is required.
In addition to the firmware released we are also releasing an update to
the RTCU IDE Simulator to support the increase in the number of available
VPL threads from 8 to 14.
Please download from www.rtcu.dk
Best regards, Logic IO
Firmware for
RTCU A9i and RTCU M10/M11 Series V4.74
Firmware version 4.74 for the RTCU A9i and M10/M11 Series has been
released.
A number of enhancements are included in this release:
-
Problem where unit assumes disconnected to network due to wrong
interpretation of CREG? response fixed.
-
String reference management problem in advanced multithreading
situations resulting in memory leak fixed.
-
Number of VPL threads increased from 8 to 14.
-
Problem where data is sometimes lost with sockDisconnect() immediately
after sockSend() fixed.
-
Problem where SMS messages can be double delivered to application in
rare reset/restart cases fixed.
-
Support for SMS messages where the sender telephone number is encoded as
packed 7 bit data (rarely used encoding scheme).
This new firmware release is available now from www.rtcu.dk.
Firmware for RTCU SA,
DIN, D4, A5/A5i and A6 V4.54
Firmware version 4.54 for the RTCU SA, RTCU DIN, RTCU A5/A5i and RTCU A6 has been
released.
A number of enhancements are included in this release:
-
20 bytes receive buffer on the RS232/RS485 channels introduced.
-
Optimized serial protocol implemenation. Upto 50% faster.
-
gsmPower() will now return to the application in a modem-lockup
situation being handled automatically in the background.
-
New functions to handle application name/version in connection with
automatic updates.
-
Problem where unit assumes disconnected to network due to wrong
interpretation of CREG? response fixed.
-
boardSetPassword() now supported in small memory model RTCU units.
-
Support for SMS messages where the sender telephone number is encoded as
packed 7 bit data (rarely used encoding scheme).
This new firmware release is available now from www.rtcu.dk.
...under development
Logic IO are always busy working on new enhancements and
products.
Currently we are working with the following:
-
Encrypted and Compressed GPRS Gateway communication.
Higher safety and lower communication costs are the result of these
coming features!
-
RTCU GPRS Deployment & Upgrade Server.
Automatic upgrade of application/firmware is made possible with this
server using the just released background update features.
-
Next release of the RTCU GPRS Gateway Professional.
-
Optimizing EIS Compiler (Enhanced Instruction Set).
This is the next generation VPL compiler with optimized instruction set
and deep dead code elimination. These advanced features will reduce the size of an
application with upto 50% and also break the current 128 KByte
limitation per task!!
These features will allow much larger programs without adding more
physical memory!
-
Visual Basic support for the RTCU Communication
Deployment Package.
-
Next release of the RTCU IDE with many enhancements,
including EIS support.
-
RTCU MX2
The "next generation" RTCU that will be a more compact design with a
powerfull 32-bit processor, extremely advanced power-management,
CAN-bus, SD-CARD support, Bluetooth and much much more...
Suggestions, comments and ideas to new features/products are always
welcomed...
For further questions or enquiries:
Logic IO ApS Jyllandsgade 54 8700
Horsens Denmark Telephone: +45 7625 0210 Fax: +45 7625 0211
info@logicio.com http://www.logicio.com
|